beautypg.com

3 -4. si unit, 3 -5. applicable manifold valve series – SMC Networks EX500 User Manual

Page 14

background image

EX500 Serial System

EX## - OME0008

- 13 -

3 -4. SI Unit

SI Unit for SV series Manifold Valve

SI Unit for VQC series Manifold Valve

SI Unit specification

Item

Specification

Models

EX500 - S001 ( -X1 )

EX500 - Q□01 ( -X1 )

Connecting
block

Solenoid valve ( Single , Double )

Relay Output Module ( 1 output , 2 output )

Solenoid valve ( Single , Double )

Number
of
connecting block

Double solenoid valve , : 8 blocks Max.
Relay Output Module ( 2 output )
Single solenoid valve , : 16 blocks Max.
Relay Output Module ( 1 output )

Double solenoid valve : 8 blocks Max.

Single solenoid valve : 16 blocks Max.

Power supply for block

24V DC

Current supply for block

0.65A Max.

0.75A Max.

Current consumption

100mA or less ( in case of rated voltage )

Short circuit
protection

Use current limit driver

Once the driver circuit is shorted, current is limited in order to de-energize the load.
Once the short circuit is fixed, the unit will self recover.

C1

or

“ 0 “

Connecting with Input Unit. M12 connector ( 8 pin, socket )
Pin NO.
1. RD + 2. RD -
3. N. C. 4. N. C.
5. N. C. 6. N. C.
7. 24V DC ( for power source )
8. 0V DC ( for power source )

Communication
connector

C2

or

“ 1“

Connecting with GW Unit. M12 connector ( 8 pin, plug )
Pin NO.
1. RD + 2. RD -
3. TD + 4. TD -
5. 24V DC ( for solenoid valve)
6. 0V DC ( for solenoid valve)
7. 24V DC ( for power source )
8. 0V DC ( for power source )

Weight

115g

105g

3 -5. Applicable Manifold Valve series

Manifold

Applicable cylinder size ( mm )

Series

Cassette

type

Tie-rod

type

40

50

63

80

100

125

SV1000

SV2000

SV3000

-

SV4000

-

VQC1000

-

VQC2000

-

VQC4000

-

Refer to the Catalogues or Technical Instruction Manual of SV and VQC series Manifold Valve
for more details.

How to Order

E X 5 0 0 - S 0 0 1

GW Unit compatible

Nil

DeviceNet

PROFIBUS-DP

-X1

Remote I/O ( RIO )

How to Order

E X 5 0 0 - Q 1 0 1

GW Unit compatible

Output specification

0 NPN output ( + COM. )

1 PNP output ( - COM. )

Nil

DeviceNet

PROFIBUS-DP

-X1

Remote I/O ( RIO )

For SI Unit

1

7

6

5

8

2

3

4

For SI Unit

2

3

4

5

8

1

7

6