EX500 Serial System

EX## - OME0008

- 26 -

6 -3. LED display

When the Input Unit Manifold is not connected, the respective COM LED of the GW Unit will not light up.
To monitor the status of COM port, it is necessary to use a Terminal Plug.
The COM LED will light up when a Terminal Plug is used. ( Refer to section 3 -6 -4 )

6 -4. Operation setting

Turn the power supply OFF when setting switches.

Open the station switch protection cover and set the dip switch with a flat blade screw driver.

COM A COM B COM C COM D

OUT

IN

R

BUS

O

I

B U S

PROCESS FIELD BUS

F

R

P

DIA

BF

SOL

RUN

GATEWAY UNIT
EX500 SERIES

Display

Content

RUN

Source ON : Lights
Source OFF : Lights off

SOL

Solenoid valve source voltage is normal :Lights
Voltage lowered to 20V or less :Lights off

BF

PROFIBUS-DP communication is normal : Lights off
PROFIBUS-DP communication is abnormal : Lights

DIA

DIA is abnormal : Lights
DIA is normal : Lights off

COM A

Communication port A is receiving data : Lights
Communication port A has no data : Lights off

COM B

Communication port B is receiving data : Lights
Communication port B has no data : Lights off

COM C

Communication port C is receiving data : Lights
Communication port C has no data : Lights off

COM D

Communication port D is receiving data : Lights
Communication port D has no data : Lights off

0

1

2

3

4

5

9

8

7

6

Figure of setting switch

SW1

SW2

ON

1 2

SW3

SW4

CAUTION