After maintenance actions, Special parts – Jackson Door-type Dishmachine TEMPSTAR GPX User Manual
Page 28
Tempstar/HH GPX Series Technical Manual 7610-002-57-32
Issued: 07-24-2006 Revised: N/A
SECTION 5: SERVICE PROCEDURES
23
19. Using the small flathead screwdriver, lift out the screen
retainer. Verify that the holes in it are free of clogs and debris.
20. Again using the small flathead screwdriver, carefully
remove the mesh screen from inside the valve body. The
screen should be taken and rinsed out to remove any debris
fouling it.
21. With the mesh screen removed, look down into the valve
and verify it is not clogged. Remove any foreign objects from
the valve body that would obstruct flow.
22. Reassemble the valve, reversing the steps needed to take
it apart. Replace defective replacement parts with new parts
from ordered kits. Ensure that components are sufficiently
tightened to prevent leakage.
AFTER MAINTENANCE ACTIONS
Reconnect the incoming water (if disconnected) and
turn on. Then restore power to the unit. Run the unit for at
least 10 minutes to ensure there are no leaks. If any problems
arise please contact your Jackson representative.
SPECIAL PARTS
Plunger and Spring Replacement Kit
06401-003-07-40
Diaphragm and O-Ring Replacement Kit (3/4”)
06401-003-07-42
110V Coil and Housing
06401-003-07-43
RINSE SOLENOID VALVE REPAIR PARTS KIT (CONTINUED)
Removing the screen retainer
Removing the mesh strainer screen
View inside the solenoid valve body