SECTION 5: SERVICE PROCEDURES

20

These dishmachines are equipped with electrical

solenoid valves to allow for automatic fill and rinse. These
valves are designed to specific tolerances and design aspects
that must be met in order to function properly.

Ecolab offers repair kits for replacing some of the

wear items associated with solenoid valves which will allow
you to save money in that replacement of these parts can take
place without removing the solenoid valve from the plumbing
assembly.

The instructions provided here are for maintenance

personnel only. Unauthorized persons should not attempt any
of the steps contained in these instructions.

Warning: many of the instructions and steps

within this document require the use of tools. Only
authorized personnel should ever perform any mainte-
nance procedure on the dishmachine!

PREPARATION

1. Power must be secured to the unit at the service

breaker. Tag or lock out the service breaker to prevent acci-
dental or unauthorized energizing of the machine.

2. Ensure that incoming water to the machine is

secured either by use of a shut-off valve or disconnecting the
incoming water line.

TOOLS REQUIRED

The following tools will be needed to perform this

maintenance evolution:

1. Small flathead screwdriver
2. Medium flathead screwdriver
2. Needle nose pliers
3. 5/16” nutdriver
4. Channel locks
5. 12” pipe wrench

TIME REQUIRED

It is estimated that it will take (1) person twenty min-

utes to perform this task, not including all of the items indicat-
ed in the section entitled “PREPARATION”.

IMPORTANT NOTES

1. Read these instructions thoroughly before

attempting this maintenance evolution. Become familiar with
the parts and what actions need to be taken. This will save
time in the long run!

2. The procedures demonstrated in this manual are

shown being performed on an AJ-44CE rack conveyor dish-
machine. The actual maintenance steps, however, apply to
any Parker style solenoid valve found on a Jackson dishma-
chine.

STEPS

1. Remove the top screw with the 5/16” nutdriver. Remove the
screw and the data plate and set to the side.

2. With the top screw and data plate removed, grasp the sole-
noid coil and gently pull up. The coil should slide up, allowing
you to remove it from the valve bonnet. If you are wanting to
replace the coil, continue on with Step 3. If you are wanting to
replace some of the internal components of the valve, pro-
ceed to step 12.

3. NOTE: Replacing the solenoid coil requires working with
the wiring of your machine. It is important that all wiring main-
tenance be performed by qualified personnel. Always verify
the wiring steps presented in this instruction with the schemat-
ic that shipped with the unit. A current schematic can also be
found in the unit’s installation manual. Before beginning any
step that involves working with wiring, ensure that the steps
located in the section entitled “Preparation” have been per-
formed. Power must be secured to the machine at the service
breaker. Failure to do so could result in severe injury to main-
tenance personnel.

RINSE SOLENOID VALVE REPAIR PARTS KIT

Removing the top screw

Removing the coil