Maintain the routing engine – Juniper Networks M5 User Manual
Page 99

Maintain the Routing Engine
•
Verify that the air flow in and out of cooling system components is not obstructed.
Maintain the Routing Engine
The Routing Engine installs into a slot in the Forwarding Engine Board (FEB) at the
rear of the chassis, as shown in Figure 3. To maintain the Routing Engines, issue the
CLI show chassis routing-engine command on a regular basis to check the status of the
Routing Engine:
user@host> show chassis routing-engine
Routing Engine status:
Temperature
35 degrees C / 95 degrees F
DRAM
768 MB
Memory utilization
16 percent
CPU utilization:
User
0 percent
Background
0 percent
Kernel
0 percent
Interrupt
0 percent
Idle
100 percent
Model
RE-2.0
Serial ID
f1000004f91d2901
Start time
2003-05-01 15:07:12 PDT
Uptime
3 days, 9 hours, 4 minutes, 5 seconds
Load averages:
1 minute
5 minute
15 minute
0.04
0.01
0.00
For further description of the output from the command, see the JUNOS Internet Software
Operational Mode Command Reference: Protocols, Class of Service, Chassis, and Management.
Maintain Hardware Components
79