Ⅵ HOW TO USE THE RS-485 TERMINAL
You can control the monitor from the controller (exclusive for this monitor) or your PC via the RS-485 terminal. For details on
operating the monitor from the PC, consult the service center.
1. Cable
Prepare a straight cable with a D-sub connector (9-pin, male) and a D-sub
connector (9-pin, male)
2. Communications Specifications
Baud Rate
: 4800/9600/19200 (factory pre-set; 4800)
Data Bits
: 8 bits
Parity
: No parity
Stop Bits
: 1
Communication Cord : ASCII Cord
3. Commands
Format
Header ID Command ID Command Content Data CR
Header
!
Control from the PC to the monitor
?
Reference from the PC to the monitor
@
Answer from the monitor to the PC
ID + Command + Data
B
Basic command
Characters
00, 01 or No data
D
Command for adjusting the picture size
00 ~ 08
U, D (U: UP, D: DOWN)
S
Command for adjusting the picture quality
00 ~ 05
U, D (U: UP, D: DOWN)
M
Command for selecting the menu item
00 ~ 0E
00, 01, 10, 11
F
Command for selecting the menu item
00 ~ 10
00, 01, 02, 03, 04, 05
W
Command for adjusting the white balance
00 ~ 05
U, D (U: UP, D: DOWN)
C
Command for inquiring for the monitor’s status
00
0 ~ 655
Communication Procedures
The following is the communication procedures.
1. Starting the communication
Receives the connection command (!XXBCN1Cr) from the PC [ Sends the monitor’s status (@XXBOKCr) to the PC
2. Performing the external control
Receives the control command (!XXXXCr) from the PC [ Sends the monitor’s status (@XXBOKCr) to the PC
* The monitor repeats these receiving and sending if necessary.
3. Terminating the communication
Receives the termination command (!XXBCN0Cr) [ Sends the monitor’s status (@XXBOKCr) to the PC
* Hand-shake communication is used. This means that after sending a command to the monitor, the PC must receive a status
return from the monitor before sending the next command.
* When the monitor is controlled by a PC via RS-485, a conversion adapter (RS-232Cp[RS-485) is also required.
4
3
2
1
9
8
5
7
6
Pin No.
IN terminal
OUT terminal
signal
signal
1
5V Power (for
controller exclusively
NC
for this monitor)
2
TD
+
TD
+
3
RD
+
RD
+
4
NC
NC
5
NC
NC
6
NC
NC
7
TD–
TD–
8
RD–
RD–
9
NC
NC
* The 5V power supply of the 1st terminal is for the controller