beautypg.com

Using the 12v triggers, Zone 2 —continued – Integra DTR-5.9 User Manual

Page 98

background image

98

Zone 2

—Continued

The 12V triggers A, B, and C can be used to turn on 12V
trigger-capable components automatically when they are
selected as the input source. The triggers can be set so
that they activate when a connected component is
selected as the input source for the main room or Zone 2.
When triggered, the output from a 12V TRIGGER OUT
goes high (+12 volts, 100 milliamperes max).

Hookup

• Use a miniplug cable to connect the AV receiver’s 12V

TRIGGER OUT A, B, or C jack to the 12 V trigger
input on a connected component.

When several components are turned on simultaneously
by using triggers A, B, and C, depending on the type of
components, a large amount of current may be drawn
momentarily. To prevent this, you can delay trigger sig-
nals A, B, and C individually. Another application for
trigger delay is eliminating the “thump” noise that’s
sometimes heard when a source component is turned on.
Delaying the trigger signal for your power amplifier so
that it’s the last component to be turned on will accom-
plish this.

Using the 12V Triggers

1

Press the [Receiver] Remote
Mode button, followed by the
[Setup] button.

The main menu appears onscreen.

2

Use the Up and Down [

]/[

]

buttons to select
“6. Miscellaneous,” and then
press [Enter].

The Miscellaneous menu appears.

ANTENNA

FM

AM

75

SIRIUS

C

B

12V TRIGGER OUT

A

6. Miscellaneous

1.Volume Setup
2.OSD Setup
3.12V Trigger A Setup
4.12V Trigger B Setup
5.12V Trigger C Setup

3

Use the Up and Down [

]/[

]

buttons to select “12V Trigger A,
B, or C,” and then press [Enter].

The 12V Trigger A/B/C Setup screen
appears.

4

Use the Up and Down [

]/[

]

buttons to select “Delay,” and use
the Left and Right [

]/[

] but-

tons to select: 0 sec, 1 sec, 2 sec,
or 3 sec.

When 0 sec is selected, the trigger sig-
nal is output as soon as the input source
is changed.

5

Use the Up and Down [

]/[

]

buttons to select an input
source, and use the Left and
Right [

]/[

] buttons to select

an option.

Off:

No trigger signal is output.

A 12-volt trigger signal is output when
the connected component is selected as
the source for:

Main:

Main room.

Zone2:

Zone 2.

Main/Z2:

Main room or Zone 2.

6

When you’ve finished, press the
[Setup] button.

Setup closes.

6-x. 12V Trigger x Setup

Delay 1sec
DVD Main/Zone2
VCR/DVR Main/Zone2
CBL/SAT Main/Zone2
GAME/TV Main/Zone2
AUX Main/Zone2
TAPE Main/Zone2
CD

Main/Zone2