TROUBLE SHOOTING

Product discharged from exhaust outlet.

S

Check for diaphragm rupture.

S

Check tightness of diaphragm nut.

Air bubbles in product discharge.

S

Check connections of suction plumbing.

S

Check ``O" rings between intake manifold and fluid caps.

S

Check tightness of diaphragm nut.

Motor blows air or stalls.

S

Check (176) check valve for damage or wear.

S

Check for restrictions in valve / exhaust.

Low output volume, erratic flow, or no flow.

S

Check air supply.

S

Check for plugged outlet hose.

S

Check for kinked (restrictive) outlet material hose.

S

Check for kinked (restrictive) or collapsed inlet material hose.

S

Check for pump cavitation - suction pipe should be sized at leastas

large as the inlet thread diameter of the pump for proper flow if high

viscosity fluids are being pumped. Suction hose must be a non-colĆ

lapsing type, capable of pulling a high vacuum.

S

Check all joints on the inlet manifolds and suction connections.

These must be air tight.

S

Inspect the pump for solid objects logged in the diaphragm chamĆ

ber or the seat area.

DIMENSIONAL DATA

(Dimensions shown are for reference only, they are displayed in inches and millimeters (mm).

15

(381 mm)

29-5/16

(744 mm)

23-3/8

(594 mm)

23-5/8

(599 mm)

3'' NPT

PD30X-AXX-XXX

13-1/2

(343 mm)

3-13/16

(97 mm)

PN 97999-639

12

(305 mm)

AIR INLET

3/4'' NPT

17/32 SLOT

(14 mm)

MATERIAL

INLET

MATERIAL

OUTLET

FIGURE 4

3'' BSP

PD30X-BXX-XXX

13

-1/2

(343 mm)

Dotted lines show optional

94085 Muffler Asm.

17-11/16

(450 mm)

1-1/2 NPT Exhaust port.

D009

OPTIONAL ACCESSORY: 66109 Airline Connection Kit