beautypg.com

1 active heatsink measurements, 2 passive heatsink measurements, Active heatsink measurements – Intel CORETM 2 DUO MOBILE 320028-001 User Manual

Page 25: Passive heatsink measurements

background image

Core™ 2 Duo Mobile Processors—Thermal Metrology

Intel® Core™ 2 Duo Mobile Processors on 45-nm process-Thermal Design Guide

TDG

June 2008

25

Order Number: 320028-001

It is worthwhile to determine the local ambient temperature in the chassis around the processor to

understand the effect it may have on the case temperature. T

LA

is best measured by averaging

temperature measurements at multiple locations in the heatsink inlet airflow. This method helps

reduce error and eliminate minor spatial variations in temperature. The following guidelines are

meant to enable accurate determination of the localized air temperature around the processor during

system thermal testing.

7.4.1

Active Heatsink Measurements

• It is important to avoid taking measurements in the dead flow zone that usually develops above

the fan hub and hub spokes. Measurements should be taken at four different locations uniformly

placed at the center of the annulus formed by the fan hub and the fan housing to evaluate the

uniformity of the air temperature at the fan inlet. The thermocouples should be placed

approximately 3 mm to 8 mm [0.1 to 0.3 in.] above the fan hub vertically and halfway between

the fan hub and the fan housing horizontally as shown in

Figure 13

(avoiding the hub spokes).

• Using an open bench to characterize an active heatsink can be useful, and usually ensures more

uniform temperatures at the fan inlet. However, additional tests that include a solid barrier above

the test motherboard surface can help evaluate the potential impact of the chassis. This barrier is

typically clear Plexiglas*, extending at least 100 mm [4 in.] in all directions beyond the edge of

the thermal solution. Typical distance from the motherboard to the barrier is 81 mm [3.2 in.]. If a

barrier is used, the thermocouple can be taped directly to the barrier with clear tape at the

horizontal location as previously described, halfway between the fan hub and the fan housing.

• For even more realistic airflow, the motherboard should be populated with significant elements

like memory cards, graphic card, and chipset heatsink. If a variable speed fan is used, it may be

useful to add a thermocouple taped to the barrier above the location of the temperature sensor

used by the fan to check its speed setting against air temperature. When measuring T

LA

in a

chassis with a live motherboard, add-in cards, and other system components, it is likely that the

T

LA

measurements will reveal a highly non-uniform temperature distribution across the inlet fan

section.

Note:

Testing an active heatsink with a variable speed fan can be done in a thermal chamber

to capture the worst-case thermal environment scenarios. Otherwise, when doing a

bench top test at room temperature, the fan regulation prevents the heatsink from

operating at its maximum capability. To characterize the heatsink capability in the

worst-case environment in these conditions, it is then necessary to disable the fan

regulation and power the fan directly, based on guidance from the fan supplier.

7.4.2

Passive Heatsink Measurements

• Thermocouples should be placed approximately 13 mm to 25 mm [0.5 to 1.0 in.] away from

processor and heatsink as shown in

Figure 14

.

• The thermocouples should be placed approximately 51 mm [2.0 in.] above the baseboard. This

placement guideline is meant to minimize the effect of localized hot spots from baseboard

components. The height above the board may vary depending on the height of the thermal

solution and form factor.