IBM THINKCENTER 8189 User Manual
Page 92

Diagnostic
Error
Code
FRU/Action
175-000-XXX
Thermal
Sensor(s)
Test
Passed
No
action
175-0XX-XXX
Thermal
Sensor(s)
failure
1.
Flash
system
2.
System
board
175-195-XXX
Thermal
Sensor(s)
Test
aborted
by
user
1.
Information
2.
Re-start
the
test,
if
necessary
175-196-XXX
Thermal
Sensor(s)
test
halt,
error
threshold
exceeded
1.
Press
F3
to
review
the
log
file
2.
Re-start
the
test
to
reset
the
log
file
175-197-XXX
Thermal
Sensor(s)
test
warning
1.
Make
sure
the
component
that
is
called
out
is
connected
and/or
enabled
2.
Re-run
test
3.
Component
that
is
called
out
in
warning
statement
4.
Component
under
test
175-198-XXX
Thermal
Sensor(s)
test
aborted
1.
If
a
component
is
called
out,
make
sure
it
is
connected
and/or
enabled
2.
Flash
the
system
and
re-test
3.
Go
to
175-199-XXX
Thermal
Sensor(s)
test
failed,
cause
unknown
1.
Go
to
2.
Flash
the
system
and
re-test
3.
Replace
component
under
function
test
175-250-XXX
175-251-XXX
Thermal
Sensor(s)
limit
error
1.
Check
fans
2.
Check
Power
supply
3.
Microprocessor
4.
System
board
185-000-XXX
Asset
Security
Test
Passed
No
action
185-XXX-XXX
Asset
Security
failure
1.
Flash
system
2.
System
board
185-278-XXX
Asset
Security
Chassis
Intrusion
1.
Assure
Asset
Security
Enabled
2.
C2
Cover
Switch
3.
System
board
201-000-XXX
System
Memory
Test
Passed
No
action
201-XXX-XXX
System
Memory
error
1.
Replace
the
memory
module
called
out
by
the
test
2.
System
board
202-000-XXX
System
Cache
Test
Passed
No
action
202-XXX-XXX
System
Cache
error
1.
Cache,
if
removable
2.
System
board
3.
Microprocessor
86
Hardware
Maintenance
Manual