POST

Error

Code

FRU/Action

101XX

Not

listed

above

1.

Modem

Adapter/A

2.

Data/Fax

Modem

3.

System

Board

4.

Riser

card

10450,

10451,

10490,

10491,

10492,

10499

Read/write

error

1.

Run

Enhanced

Diagnostics

2.

Hard

Disk

Drive

3.

System

Board

4.

Riser

card

10452

Seek

test

error

Run

Enhanced

Diagnostics

10453

Wrong

drive

type?

Information

only

10454

Sector

buffer

test

error

Run

Enhanced

Diagnostics

10455,

10456

Controller

error

Run

Enhanced

Diagnostics

10459

Drive

diagnostic

command

error

Information

only

10461

Drive

format

error

Run

Enhanced

Diagnostics

10462

Controller

seek

error

Run

Enhanced

Diagnostics

10464

Hard

Drive

read

error

Run

Enhanced

Diagnostics

10467

Drive

non-fatal

seek

error

Run

Enhanced

Diagnostics

10468

Drive

fatal

seek

error

Run

Enhanced

Diagnostics

10469

Drive

soft

error

count

exceeded

Run

Enhanced

Diagnostics

10470,

10471,

10472

Controller

wrap

error

Run

Enhanced

Diagnostics

10473

Corrupt

data.

Low

level

format

might

be

required

Information

only

10480

1.

Hard

Disk

Drive

(ESDI)

2.

Drive

Cable

3.

System

Board

10481

ESDI

drive

D

seek

error

Run

Enhanced

Diagnostics

10482

Drive

select

acknowledgement

bad

Run

Enhanced

Diagnostics

106X1

1.

Check

Configuration

2.

Ethernet

Adapter

Chapter

7.

Symptom-to-FRU

Index

101