IBM THINKCENTER 8189 User Manual
Page 77

Diagnostic
Error
Code
FRU/Action
000-035-XXX
BIOS
Reset
Condition
detected
1.
Flash
the
system
2.
System
board
000-036-XXX
BIOS
Register
error
1.
Flash
the
system
2.
Boot
block
3.
System
board
000-038-XXX
BIOS
Extension
failure
1.
Flash
the
system
2.
Adapter
card
3.
System
board
000-039-XXX
BIOS
DMI
data
error
1.
Flash
the
system
2.
System
board
000-195-XXX
BIOS
Test
aborted
by
user
1.
Information
2.
Re-start
the
test,
if
necessary
000-196-XXX
BIOS
test
halt,
error
threshold
exceeded
1.
Press
F3
to
review
the
log
file
2.
Re-start
the
test
to
reset
the
log
file
000-197-XXX
BIOS
test
warning
1.
Make
sure
the
component
that
is
called
out
is
connected
and/or
enabled
2.
Re-run
test
3.
Component
that
is
called
out
in
warning
statement
4.
Component
under
test
000-198-XXX
BIOS
test
aborted
1.
If
a
component
is
called
out,
make
sure
it
is
connected
and/or
enabled
2.
Flash
the
system
and
re-test
3.
Go
to
000-199-XXX
BIOS
test
failed,
cause
unknown
1.
Go
to
2.
Flash
the
system
and
re-test
3.
Replace
component
under
function
test
000-250-XXX
BIOS
APM
failure
1.
Flash
the
system
2.
System
board
000-270-XXX
BIOS
ACPI
failure
1.
Flash
the
system
2.
System
board
001-000-XXX
System
Test
Passed
No
action
001-00X-XXX
System
Error
System
board
001-01X-XXX
System
Error
System
board
001-024-XXX
System
Addressing
test
failure
System
board
001-025-XXX
System
Checksum
Value
error
1.
Flash
the
system
2.
System
board
Chapter
7.
Symptom-to-FRU
Index
71