TROUBLE SHOOTING

Product discharged from exhaust outlet.

S

Check for diaphragm rupture.

S

Check tightness of (14) diaphragm screw.

Air bubbles in product discharge.

S

Check connections of suction plumbing.

S

Check “O” rings between intake manifold and inlet side fluid caps.

S

Check tightness of (14) diaphragm screw.

Motor blows air or stalls.

S

Check (176) check valve for damage or wear.

S

Check for restrictions in valve / exhaust.

Low output volume, erratic flow, or no flow.

S

Check air supply.

S

Check for plugged outlet hose.

S

Check for kinked (restrictive) outlet material hose.

S

Check for kinked (restrictive) or collapsed inlet material hose.

S

Check for pump cavitation -- suction pipe should be sized at least as

large as the inlet thread diameter of the pump for proper flow if high

viscosity fluids are being pumped. Suction hose must be a non-col-

lapsing type, capable of pulling a high vacuum.

S

Check all joints on the inlet manifolds and suction connections.

These must be air tight.

S

Inspect the pump for solid objects logged in the diaphragm chamber

or the seat area.

DIMENSIONAL DATA

(Dimensions shown are for reference only, they are displayed in inches and millimeters (mm).

Figure 4

INLET

OUTLET

Exhaust Port

1-1/2 - 11-1/2 N.P.T.

21-5/8”

(548.2 mm)

16-3/16”

(411.1 mm)

12”

(304.8 mm)

3”

(76.2 mm)

9-1/16”

(230.2 mm)

10-1/16”

(255.6 mm)

19-11/32”

(491.3 mm)

9/16” Slot

(14.3 mm)

10-1/16”

(255.6 mm)

24-3/4”

(628.7 mm)

2-1/2”

(63.5 mm)

Air Inlet

3/4 - 14 N.P.T.F. - 1

26-9/32”

(667.4 mm)

Dotted lines show optional

67213 muffler kit.

2-1/2” Tri-Clamp

2-1/2” Tri-Clamp

Dotted lines show optional

67263 muffler assembly.

13-9/16”

(344.5 mm)

PN 97999-1114