beautypg.com

Lighting pilot for the first time lighting pilot, Pilot – Monessen Hearth LEXINGTON LX32DV User Manual

Page 35

background image

51D0528

35

LX Series Direct Vent Gas Fireplace

opeRAtING INStRuctIoNS

AppRoVeD LeAK teStING MethoD

You may check for gas leaks with the following
methods only:

Soap and water solution

An approved leak testing spray

Electronic sniffer

Note: Remove any excessive pipe
compound from the connections.
excessive pipe compound can set off
electronic sniffers.

1. Depress and turn knob counterclockwise

to

pilot position.

2. Depress fully and hold pilot gas knob. Depress piezo

ignitor as many times as needed to ignite the pilot.
Keep knob fully depressed for a few seconds.
Release and check that pilot continues to burn.

If the pilot does not stay lit, repeat steps 1 and 2.

Figure 49 -
Pilot Position

Check for gas leaks in each of the following locations:

Pipe from the gas supply line connection to the gas valve

Burner connections

Field made joints / gas shutoff valve

Pilot

Factory made joints

Each joint or connection

All joints on valve and control body

LIGhtING pILot FoR the FIRSt tIMe

LIGhtING pILot

W

ARNING

If using a soap and water solution
to test for leaks, Do Not spray
solution onto control body.

DANG

e

R

Never check for gas leak
with open flame!

PILOT

OF

   

   

 P

IL

O

    ON

FP1935
control knob pilot

This manual is related to the following products: