Status, error, and service messages, Status, error, and service messages 121 – Minolta Magicolor 2200 User Manual
Page 129
Status, Error, and Service Messages
121
Status, Error, and Service Messages
Status, error, and service messages are displayed in the control panel message window.
They provide information about your printer and help you locate many problems. When
the condition associated with a displayed message has changed, the message is cleared
from the window.
The image is
offset.
The OPC drum cartridge is
defective.
Check the OPC drum cartridge. If necessary, replace the
entire drum kit.
The fuser oil roller is
defective.
Check the fuser oil roller. If necessary, replace it.
The fuser unit is defective.
Check the fuser unit. If necessary, replace it.
Colors look
drastically
wrong.
The toner cartridges are
incorrectly installed.
Remove the toner cartridges and reinstall them.
The color
has a poor
reproduction
or has poor
color density.
The paper image transfer is
defective.
Check the OPC drum cartridge. If necessary, replace the
entire drum kit.
The Auto-Image Density
Control (AIDC) detection
sensor is dirty.
Open the front cover. Lift up the transfer belt release lever
to the 12 o’clock position. Next, return the lever to the
3 o’clock position. Repeat this operation several times.
(This cleans the surface of the AIDC detection [image dark-
ness] sensor.)
Symptom
Cause
Solution