Multitech MT1432BA User Manual
Page 45
45
Chapter 5 - Command Mode
CONTROL RS232C
&C
Carrier Detect Control
INTERFACE
&D
Data Terminal Ready Control
&R
Clear To Send Control
&S
Data Set Ready Control
&RF
CTS/RTS Control
&SF
DSR/CD Control
CONFIGURE
&E0
Normal Mode
ERROR
&E1
Auto-Reliable Mode
CORRECTION
&E2
Reliable Mode
#L0
Negotiate V.42 Mode During Handshake
#L1
MNP On/LAPM Off
#L2
LAPM On/MNP Off
#L3
Direct LAPM/Phase Out Handshake
$A
Auto-Reliable Buffering
$F
Enable/Disable Auto-Reliable Fallback Character
$R
Retransmit Count
$E
Error Correction at 300 bps
CONFIGURE
&E3
Flow Control Disabled
FLOW CONTROL
&E4
Hardware Flow Control
&E5
Xon/Xoff Modem-Initiated
&E6
Xon/Xoff Modem Responds/No Pass-Through
&E7
Xon/Xoff Modem Responds/Pass-Through Allowed
#X
Send Single/Multiple Xoff Characters
&E8
Enq/Ack Off
&E9
Enq/Ack On
&E10
Normal Mode Modem Flow Control Off
&E11
Normal Mode Modem Flow Control On
&E12
Computer-Initiated/Off
&E13
Computer-Initiated/On
&BS
Maximum Block Size
$EB
10/11 bit Asynchronous Format
#P
Parity Selection
CONFIGURE DATA
&E14
Data Compression Disabled
COMPRESSION
&E15
Data Compression Enabled
CONFIGURE SPEED
$BA0
Speed Conversion On
CONVERSION
$BA1
Speed Conversion Off
$MB
Set modem speed (e.g.,$MB14400)
$SB
Set serial port speed (e.g.,$SB57600)
EXECUTE
$H
Help
IMMEDIATE
I
Product Code Inquiry
ACTION
I 9
Windows 95 Autodetect Inquiry (2834 Series only)
COMMANDS
L5
List Current Operating Parameters
L6
List S-Register Values
L7
List additional Configuration Parameters
L8
List On-Line Diagnostics
H
Off Hook
+++AT
Escape Sequence: Entering Command Mode while On-Line
%E
Escape Sequence Options...Entering Command Mode while On-Line
A
Force Answer Mode
O
Exit Command Mode/Go Back On-Line