MultiModemBA User Guide
Command
Values
Description
Sr?
r = 0-11, 13,
Reads value of Register “r” and displays
15-19, 24-26,
value in 3-digit Decimal format.
30, 32 or 34...
$SBn
n = speed
2834 Series:
$SB300 selects 300 bps at serial port.
$SB1200 selects 1200 bps at serial port.
$SB2400 selects 2400 bps at serial port.
$SB4800 selects 4800 bps at serial port.
$SB9600 selects 9600 bps at serial port.
$SB19200 selects 19,200 bps at serial port.
$SB38400 selects 38,400 bps at serial port.
*
$SB57600 selects 57600 bps at serial port.
$SB115200 selects 115200 bps at serial port.
1432 Series:
$SB300 selects 300 bps at serial port.
$SB1200 selects 1200 bps at serial port.
$SB2400 selects 2400 bps at serial port.
$SB4800 selects 4800 bps at serial port.
$SB9600 selects 9600 bps at serial port.
$SB19200 selects 19,200 bps at serial port.
$SB38400 selects 38,400 bps at serial port.
*
$SB57600 selects 57600 bps at serial port.
932 Series:
$SB300 selects 300 bps at serial port.
$SB1200 selects 1200 bps at serial port.
$SB2400 selects 2400 bps at serial port.
$SB4800 selects 4800 bps at serial port.
$SB9600 selects 9600 bps at serial port.
$SB19200 selects 19,200 bps at serial port.
*
$SB38400 selects 38400 bps at serial port.
&SFn
n = 0 or 1
*
&SF0 selects DSR follows CD.
&SF1 selects DSR independent.
&Sn
n = 0, 1 or 2
&S0 forces Data Set Ready On.
*
&S1 lets Data Set Ready act normally.
&S2 Data Set Ready drop is regulated by S24 on
disconnect.
$SPn
n = 0 or 1
*
$SP0 disables UUCP Spoofing
$SP1 enables UUCP Spoofing
T
Modem will tone-dial numbers following the T.
&Tn
n = 4 or 5
&T4 means Enable Response to Request for
Remote Digital Loopback.
*
&T5 means Disable Response to Request for
Remote Digital Loopback.
#Tn
n = 0 or 1
#T0 turns off Trellis Coded Modulation
*
#T1 turns on Trellis Coded Modulation
* Factory Default Setting