Multitech MT1432BA User Manual
Page 144
144
MultiModemBA User Guide
S-REGISTER
UNIT
RANGE
DEFAULT
DESCRIPTION
S29
1
1-255
20
Specifies the amount of idle time can elapse
between AT commands after the SETUP
password has been entered
S30
min 0-255
0
Inactivity timer used to disconnect modem.
S32
100mSec 0-255
20
Sets time that modem waits for a
sequence execution.
S34
ASCII
0-60
10
Buffer size for number of characters in AT
command string after on-line escape
sequence, before buffer is cleared and
escape sequence aborted.
S36
1 second 0-255
0
S36 sets the time between DTR inactive and
the modem going off-hook (busy-out).
S37
1 second 0-255
5
S37 sets the time allowed DTR active and
the modem responding on-hook (not busy).
* S48
N/A
33, 31,
0
S48 sets maximum speed modem connects
28, 26, 24,
within scope of Enhanced V34
21, 19, 16,
mode (e.g., S48 = 21 means
14, 12, 96
maximum connect speed is
and 48
21.6K)
‡
. This register is useful when line
conditions will not support higher V34
speeds. The default value is 0, which
indicates a connection attempt of 28.8K.
‡
lower speeds are still enabled.
* 2834 Series only