Appendix D - AT Command Summary
Password Command Summary
Command
Description
#Ixxxxxxxxxx
Login Password is any keyboard characters (x)
(upper/lower case sensitive), minimum 6 and
maximum 10 characters. The default Login
Password is #IMULTI-TECH.
#Syyyyyyyyyy
Setup Password is any keyboard characters (y)
(upper/lower case sensitive), minimum 6 and
maximum 10 characters. The default Setup
Password is #SMODEMSETUP.
V.25bis Commands
Command
Description
$Vn
$V0 returns modem to AT command mode when in
V.25bis mode.
$V1 enables V.25bis mode of operation.
$V2 allows modem to receive one V.25bis command
while in AT command mode without leaving AT
command mode.
$V5 DSR follows DTR in V.25bis mode.
$V6 DSR does not follow DTR in V.25bis mode.
CSPs
Changes the serial bps rate.
CSP0300 - 300 bps
CSP1200 - 1200 bps
CSP2400 - 2400 bps
CSP4800 - 4800 bps
CSP9600 - 9600 bps
CSP19200 - 19200 bps
CSP38400 - 38400 bps
CSP57600 - 57600 bps (2834 and 1432 models
only)
CSP115200 - 115200 bps (2834 models only)
CRNdd
Dials phone number dd where dd can be up to 20
characters (0 through 9, *, #, P, T and :). Phone
number is checked against the Delayed and
Forbidden Number lists before dialed.
CRIdd;nn
Dials dd same as CRN Command and ignores nn
identification string. The disregard or connect to
incoming calls commands are used for auto-answer
operations.
DIC or CIC
DIC stops the modem from answering incoming
calls.
CIC causes the modem to answer incoming calls.