The valid options for printer Port Settings are shown below. The
default values are shown in bold.
Baud rate
1200, 2400, 4800, 9600, 19200
Word length
7 or 8
Stop bits
1 or 2
Parity
Odd, Even, None
Flow control
None, Xon/Xoff, DTR, CTS
Reset
Yes or No
Error
Description/Action
409
Printer memory is full.
410
Parity mismatch.
411
Framing error (baud rate mismatch).
412
Flow control mismatch.
413
Receive buffer is full. Check flow control settings.
414
Internal keyboard buffer is full or you need a new
keypad.
427
Format name must be 1 to 8 characters inside quotes or
a printer-assigned name ("").
428
Batch name is invalid or graphic not found.
429
A field number appears more than once in a format.
430
The format uses a graphic file that cannot be found.
433
The batch references a field number that does not exist
in the format.
497
Error occurred during the parallel port loop back test.
499
Error occurred during the serial port loop back test.
11 - 10 Troubleshooting