beautypg.com

Madrigal Imaging MP-9 User Manual

Page 107

background image

Notes: 1. Blanking can be increased with left and right blanking controls

2. Retrace fixed as Short in ranges 45–60 kHz and 100–152 kHz

despite user setting

3. Defl. retrace time must be less than the max. blanking duration
4. Horizontal blanking duration of the source must be more than

the max. blanking duration of the projector to avoid cutting off
the left or right edge of the source image.

5. Max. Blanking duration of the projector must be compatible with

all known sources (at the specific source frequency).

6. Max. Blanking duration of the projector restricted to 1.5µs for

operation in the range 120 kHz–152kHz.

High Voltage

34.9 KV regulated to better than ±1%

Power

Requirements

90 VAC to 264 VAC universal input

Line Frequency: 50 to 60 Hz nominal

Power: 650 watts maximum

Power factor corrected

Inputs

Built-in RGBHV interface. Optional interface modules install in
interface slot

Built-in RS-232 for computer control, with loop-thru for connection
of multiple projectors

HDTV compatible with optional interface module

Optional Source

Expansion

The Signal Switcher allows use of nine additional input modules. Up
to nine switchers can be connected

Maximum Number of Inputs: 78

Control Features

Multi-language software (user selectable)

Menu driven interface with on-screen help

Built-in set up tutorials

Auto power up after power interruption

Six built-in test patterns

Internal frequency generator

Programmable events and real time clock

Servicing

Modular design for ease of servicing

Most service adjustments are made using the keypad

SPECIFICATIONS

5.3