beautypg.com

Important, Warning, This is a required in-warranty repair procedure – Manitowoc Ice CM MODEL STH003 User Manual

Page 80: Securely in place

background image

80

REPLACING PRESSURE CONTROLS
WITHOUT REMOVING REFRIGERANT
CHARGE
This procedure reduces repair time and cost. Use it
when any of the following components require
replacement, and the refrigeration system is
operational and leak-free.

• Fan cycle control

• High pressure cut-out control

• High side access valve

• Low side access valve

IMPORTANT

This is a required in-warranty repair procedure.

1. Disconnect power to the ice machine.
2. Follow all manufacturers’ instructions supplied with

the pinch-off tool. Position the pinch-off tool
around the tubing as far from the pressure control
as feasible. (See the figure on next page.) Clamp
down on the tubing until the pinch-off is complete.

WARNING

Do not unsolder a defective component. Cut it out of
the system. Do not remove the pinch-off tool until
the new component is

securely in place.

3. Cut the tubing of the defective component with a

small tubing cutter.

4. Solder the replacement component in place. Allow

the solder joint to cool.

5. Remove the pinch-off tool.
6. Re-round the tubing. Position the flattened tubing

in the proper hole in the pinch off tool. Tighten the
wing nuts until the block is tight and the tubing is
rounded.

NOTE: The pressure controls will operate normally
once the tubing is re-rounded. Tubing may not re-
round 100%.