NOTE: THESE CHARACTERISTICS MAY
VARY DEPENDING ON OPERATING
CONDITIONS.
Cycle Times
Freeze Time + Harvest Time = Cycle Time
FREEZE TIME
WATER TEMPERATURE
°F/°C
HARVEST
TIME
AIR TEMP.
ENTERING
CONDENSER
°F/°C 50/10.0 70/21.1 90/32.2
70/21.1
15.6-17.8
15.3-17.4 15.6-17.8
80/26.7
16.6-18.9
17.0-19.4 17.4-19.8
90/32.2
17.4-19.8
19.1-21.7 18.2-20.7
100/37.8
19.2-22.1
19.8-22.7 22.4-25.4
110/43.3
24.9-28.2
25.7-29.1 31.4-35.5
1.0-3.5
Times in minutes
24 Hour Ice Production
WATER TEMPERATURE
°F/°C
AIR TEMP. ENTERING
CONDENSER
°F/°C
50/10.0 70/21.1 90/32.2
70/21.1
53 54 53
80/26.7
50 49 48
90/32.2
48 44 46
100/37.8
40 39 38
110/43.3
35 34 28
Based on the average weight of 1 harvest cycle 0.63 – 0.71 lb.
Nominal Individual Cube Weight 0.70 ounces
Cubes Per Harvest Cycle 16
Operating Pressures
FREEZE CYCLE
HARVEST CYCLE
AIR TEMP.
ENTERING
CONDENSER
°F/°C
DISCHARGE
PRESSURE
PSIG
SUCTION
PRESSURE
PSIG
DISCHARGE
PRESSURE
PSIG
SUCTION
PRESSURE
PSIG
50/10.0
125-70 18-0 50-75 20-55
70/21.1
135-95 18-0 65-85 35-60
80/26.7
165-115 19-2 75-100 40-70
90/32.2
195-135 20-3 85-120 40-70
100/37.8
235-165 24-5 100-135 50-80
110/43.3
255-185 28-7 110-155 50-90
Suction pressure drops gradually throughout the freeze cycle