Section 4 − installation, 1. specifications, 2. ih/ts installation – Miller Electric IH User Manual
Page 12

OM-203 185 Page 8
SECTION 4 − INSTALLATION
4-1. Specifications
Specification
Description
Overall Dimensions
Height: 10 in (254 mm); Width: 14-1/2 in (368 mm); Depth: 16 in (406 mm)
Weight
Net: IH/TS (no recorder) 13.1 lb (5.9 kg); IH/TS (digital recorder) 21.1 lb (9.6 kg)
Type Of Input Power
24 Volts DC, 115 Volts AC
Memory Capacity
One Program Up To 8 Segments
Control Capacity
Single Power Source Control
Operating Temperature Range
41
°
To 104
°
F (5
°
To 40
°
C)
Storage Temperature Range
−4
°
To 122
°
F (−20
°
To 50
°
C)
Reference the controller and recorder manuals for additional information.
Ref. 802 905-A / 802 900
4-2. IH/TS Installation
1
1
Tools Needed:
3/8, 5/16 in
Y Turn Off and disconnect
input power.
5 kW System
1. Temperature
Control/Recorder
2. 5kW Mounting Bracket
3. Screw, 10-32 (4)
Install and secure IH/TS to mount-
ing bracket using supplied #10
screws.
4. 5kW Power Source Case
5. Case Sheet Metal Screw (4)
Remove case sheet metal screws
from both top left and right sides of
unit. Install mounting bracket to
power source and secure by rein-
stalling sheet metal screws.
25 kW System
6. 25 kW Power Source Case
7. Rear Mounting Bracket
8. Screw, 1/4-20 (2)
Remove front and middle mounting
screws from top of Item 6 case. Lo-
cate IH/TS and reinstall front
mounting screws. Locate rear
mounting bracket, and secure with
supplied 1/4-20 screws. Reinstall
middle mounting screws to secure
bracket to case.
3
4
6
2
8
8
7
5
4