Minolta CN3101e User Manual
Page 195
Appendixes
186
•
E-mail/Internet FAX Transmission Setting
Display Procedure
Click the “Network” tab and then select “E-mail/Internet FAX” – “Send.”
Screen Description
SMTP Server
: Set the IP address of the SMTP server.
Port Number
: Set the port number of the SMTP server.
(The default value of “25” is generally used.)
SMTP Connection Timeout : Set the communications timeout with the SMTP
server.
Setting values
: 30 to 300 sec.
Maximum E-mail Size
: Set the maximum size of transmission mail
capacity.
Setting values
: No Limitation, 100 to 3000 KB (100 increments)
Binary Division
: Set whether to divide mail exceeding the
maximum size into two or more mails (in units of
binary).
Setting values
: Yes, No
4334P175CA