Summary of audible/visual notifications, Fixed-word display keypads – Garmin FA168CPS User Manual
Page 48
– 48 –
Summary of Audible/Visual Notifications
Summary of Audible/Visual Notifications
Summary of Audible/Visual Notifications
Summary of Audible/Visual Notifications
Fixed-Word Display Keypads
SOUND CAUSE
DISPLAY
LOUD,
INTERRUPTED*
Keypad & Ext.
FIRE ALARM
FIRE
is displayed; zone number of zone in
alarm is displayed. If a fire alarm is manually
activated, zone number 95 will be displayed.
LOUD,
CONTINUOUS*
Keypad & Ext.
BURGLARY/AUDIBLE
EMERGENCY ALARM
ALARM
is displayed. Zone number of zone in
alarm is also displayed.
ONE SHORT BEEP
(not repeated)
Keypad only
a. SYSTEM DISARM
b. SYSTEM ARMING ATTEMPT
WITH AN OPEN ZONE.
c. BYPASS VERIFY
a. READY indicator light comes on.
b. Number of the open protection zone displayed.
c. Zone numbers of the bypassed protection
zones are displayed (one beep is heard for
each zone displayed). Subsequently, BYPASS
is displayed.
ONE SHORT BEEP
(about every 30
secs)
Keypad only
a. SYSTEM IS IN TEST MODE
b. LOW BATTERY AT A
TRANSMITTER
c. SYSTEM WILL AUTOARM
WITHIN 10 MINUTES
a. Opened zone numbers will appear.
b. BAT displayed with zone number of
transmitter.
c. No special display.
TWO SHORT BEEPS
Keypad only
ARM AWAY or MAXIMUM
AWAY is displayed. Red ARMED indicator is lit.
THREE SHORT
BEEPS
Keypad only
a. ARM STAY, NIGHT-STAY, OR
INSTANT
b. ZONE OPENED WITH
SYSTEM IN CHIME MODE.
a. STAY or INSTANT is displayed. Red
ARMED indicator is lit.
b. CHIME displayed; zone number of open
protection zone will be displayed if the [
∗]
key is pressed.
RAPID BEEPING
Keypad only
a. TROUBLE
b. MEMORY OF ALARM
c. SYSTEM LOW BATTERY
d. EXT. SOUNDER WIRING FAIL
e. LAST 10 SEC of EXIT DELAY
a. CHECK
displayed. Zone number of troubled
protection zone is displayed.
b. FIRE or ALARM is displayed; zone number
of zone in alarm is displayed
c. BAT displayed with no zone ID number.
d. CHECK 70
is displayed.
e. No special display.
SLOW BEEPING
Keypad only
a. EXIT DELAY WARNING
b. ENTRY DELAY WARNING
a. AWAY is displayed.
b. Exceeding the entry delay time without
disarming causes alarm.
* If a bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.