8 user management, Anagement – GE MULTILINK ML1200 User Manual
Page 20
1–12
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL
INTRODUCTION
CHAPTER 1: INTRODUCTION
1.4.8
User Management
A maximum of five users can be added per switch. Users can be added, deleted or
changed from a manager level account. There can be more than one manager account,
subject to the maximum number of users on the switch being restricted to five.
To add a user, use the
add
command as shown below. The user name has to be a unique
name. The password is recommended to be at least 8 characters long with a mix of upper
case, lower case, numbers and special characters.
add user=
The following example adds a user “peter” with manager-level privilege:
ML1200#
user
ML1200(user)##
add user=peter level=2
Enter User Password:******
Confirm New Password:******
ML1200(user)##
To delete a user, use the
delete
command as shown below.
delete user=
The following example deletes the user “peter”:
ML1200(user)##
delete user=peter
Confirm User Deletion(Y/N):
Y
User successfully deleted
ML1200(user)##
The syntax to modify a password is shown below:
passwd user=
The following example changes the password for user “peter”.
ML1200(user)##
passwd user=peter
Enter New Password:******
Confirm New Password :******
Password has been modified successfully
ML1200(user)##
The syntax to modify the privilege level for a specific user is shown below:
chlevel user=
The following example modifies the privilege level of user “peter” to Operator privileges.
ML1200(user)##
chlevel user=peter level=1
Access Permission Modified
ML1200(user)##
The syntax to set the access privileges for telnet and Web services is shown below:
useraccess user=
The following example sets the access privileges for telnet and Web services.
ML1200(user)##
useraccess user=peter service=telnet disable
Telnet Access Disabled.