GE MULTILINK ML1200 User Manual
Page 132

7–8
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL
ACCESS USING RADIUS
CHAPTER 7: ACCESS USING RADIUS
Setting port control parameters (continued)
ML1200(auth)##
reauth port=1 status=enable period=300
Successfully set re-authentication parameter(s)
ML1200(auth)##
shoW-port reauth
Port
Reauth Status
Reauth Period (sec.)
=========================================
1
Enabled
300
2
Enabled
3600
3
Enabled
3600
4
Enabled
3600
5
Enabled
3600
6
Enabled
3600
ML1200(auth)##
show-stats port=3
Port 3 Authentication Counters
authEntersConnecting
: 3
authEapLogoffsWhileConnecting
: 0
authEntersAuthenticating
: 3
authAuthSuccessesWhileAuthenticating
: 2
authAuthTimeoutsWhileAuthenticating
: 0
authAuthFailWhileAuthenticating
: 0
authAuthReauthsWhileAuthenticating
: 0
authAuthEapStartsWhileAuthenticating
: 1
authAuthEapLogoffWhileAuthenticating
: 0
authAuthReauthsWhileAuthenticated
: 0
authAuthEapStartsWhileAuthenticated
: 0
authAuthEapLogoffWhileAuthenticated
: 0
backendResponses
: 5
backendAccessChallenges
: 2
backendOtherRequestsToSupplicant
: 0
backendNonNakResponsesFromSupplicant
: 2
backendAuthSuccesses
: 2
backendAuthFails
: 0
ML1200(auth)##
trigger-reauth port=3
Successfully triggered re-authentication
ML1200(auth)##
This command forces the
authentication period on port #1
every 5 minutes; all other ports are
force authenticated every hour as
indicated by the
show-port reauth
command below.