View from top, Connections in back of generator, 8 optional accessories – Guardian Technologies QUIETPACT 40LP 004701-0 User Manual
Page 32: 3 battery cable connections, 4 battery compartment, 1 remote start/stop panel, Figure 2.16 – connecting battery cables, Figure 2.17 – remote panel plug-in receptacle, Figure 2.18 – optional remote panel
0
2.7.3 battery cable connectIons
1. Connect the battery cable from the battery post or
terminal indicated by a POSITIVE, POS or (+) to
the lug on the starter contactor (Figure 2.16).
NOTE:
Check to be sure the battery cable boot for the
starter cable has been installed.
2. Connect the battery cable from the battery post
indicated by a NEGATIVE, NEG or (-) to the
frame ground connection (Figure 2.16).
3. Connect cables so the connectors are clean
and tight.
Figure 2.16 – Connecting Battery Cables
342.2
[13 1/2"]
778.9
[30 11/16"]
REF.
FRONT DOOR ACCESS FOR
ALL REQUIRED MAINTENANCE
REMOTE PANEL
CONNECTOR
500.2
[19 11/16"]
REF.
AC OUTPUT
HARNESS
HOT AIR
EXHAUST
TAIL PIPE
EXIT
OIL DRAIN
AIR
INTAKE
48.1
[1 7/8"]
222.7
[8 3/4"]
300.7
[11 13/16"]
369.7
[14 9/16"]
688.3
[27 1/8"]
29
[1 1/8"]
55.5
[2 3/16"]
376.5
[14 13/16"]
5/16"-18 WELDNUTS
(6 PLACES)
82.5
[3 1/4"]
343.4
[13 1/2"]
423.2
[16 11/16"]
717.7
[28 1/4"]
50.8
[2"]
118
[4 5/8"]
223.5
[8 13/16"]
60
[2 3/8"]
210
[8 1/4"]
176.6
[6 15/16"]
83.5
[3 5/16"]
429.5
[16 15/16"]
414.5
[16 5/16"]
360.5
[14 3/16"]
63.5
[2 1/2"]
416
[16 3/8"]
170
[6 11/16"]
79
[3 1/8"]
101
[4"]
TYP.
6.7
[1/4"]
736.4
[29"]
476.4
[18 3/4"]
36.5
[1 7/16"]
[1 7/16
[1 7/16
39.6
[1 9/16"]
69.6
[2 3/4"]
34.3
[1 3/8"]
71.2
[2 13/16"]
211.3
[8 5/16"]
NEG. BAT.
CONNECTION
POS. BAT.
CONNECTION
LP FUEL INLET
VIEW FROM TOP
NOTE: ALL AIR INTAKES AND EXHAUST OUTLETS MUST BE
KEPT CLEAR OF ANY OBSTRUCTIONS. ALL OPEN AREA
IS REQUIRED FOR COOLING.
CONNECTIONS IN
BACK OF GENERATOR
2.7.4 battery coMpartMent
Install the generator battery in its own, vented com-
partment. Place the battery compartment away from
any source of heat, sparks or flame.
Provide ventilation openings in the battery compart-
ment. The minimum size of openings should be 2
square inches at the top of the compartment. Mount
the battery on a strong, rigid supporting structure,
where leaks and spills of battery fluid will not cause
damage.
2.8 optIonal accessorIes
A plug-in receptacle (Figure 2.17) is provided on
the generator set. Use this receptacle to connect an
optional remote-mounted start/stop panel to the
generator. Installation of such a panel will permit
starting and stopping the generator engine from any
convenient location inside the vehicle.
Figure 2.17 – Remote Panel Plug-in Receptacle
12.00"
14
0
17
15
18
14A
1
3
2
5
4
6
0
14
17
18
14A
15
15
17
14A
18
14
0
No.
WIRE
WIRE
COLOR
RED
YELLOW
ORANGE
WHITE
BLUE
BROWN
12.0 (305)
LENGTH (mm)
12.0 (305)
12.0 (305)
12.0 (305)
12.0 (305)
12.0 (305)
FUNCTION
GROUND
ENGINE RUN SIGNAL
12 VDC
START
STOP
PRIME
P/N: 0D9099-B
2.8.1 reMote start/stop panel
A remote mounted Start/Stop panel (Figure 2.18) is
available that allows the user to start and stop the
generator engine conveniently from inside the vehicle.
The remote panel includes a Start/Stop switch, hour-
meter, generator run lamp, a fuel prime switch, and
a wire harness. The hourmeter should be used in
conjunction with the maintenance operations found
in Part I of this manual.
Figure 2.18 – Optional Remote Panel
PRIME
FUEL
STOP
RUN
section 2 – Installation
recreational vehicle generator