3 cooling and ventilating air, Danger, 5 compartment floor cutouts – Guardian Technologies QUIETPACT 40LP 004701-0 User Manual
Page 25: 1 generator airflow, All measurements are in millimeters, 25.4 mm = 1, Recreational vehicle generator, View from top, Connections in back of generator

2.2.5 coMpartMent Floor cutouts
Provide openings in the generator compartment for
the following items (Figure 2.7):
• Engine exhaust and cooling air outlets
• Generator cooling air inlet
• Four holes for passage of generator mounting
bolts. See Section 2.1.4.
danger
Fuel lines and exhaust piping must not pen-
etrate into the vehicle living area.
2.3 coolIng and ventIlatIng aIr
It is absolutely essential that an adequate flow of
air for cooling, ventilating and engine combustion
be supplied to the generator set. Without sufficient
airflow, the engine/generator quickly overheats. Such
overheating can cause serious operating difficulties
and also may cause fire and personal injury. The
installer must make sure that sufficient air is avail-
able to the generator for cooling, ventilating and
combustion. The installer also must provide for a
path for exhausting the cooling air to the exterior of a
compartment, if so equipped.
danger
Never use discharged cooling air for heating or
permit such air to enter the vehicle interior. This
air contains deadly carbon monoxide gas and
other poisonous, flammable or explosive gases.
2.3.1 generator aIrFlow
Engine operation drives cooling fans for the two-stage
cooling air system. A pressure fan draws cooling air
into the bottom right side of the generator (Figure
2.8). This airflow cools the engine/generator and elec-
tronic components. The second part of the cooling
system, a suction fan, draws air that is heated from
a hot engine into a collector compartment at the left
side of the unit. This heated air (although cooler than
exhaust muffler) is then deflected out the bottom
toward the ground.
section 2 – Installation
recreational vehicle generator
Figure 2.7 – Compartment Floor Cutout (Drawing 0F4610)
342.2
[13 1/2"]
778.9
[30 11/16"]
REF.
FRONT DOOR ACCESS FOR
ALL REQUIRED MAINTENANCE
REMOTE PANEL
CONNECTOR
500.2
[19 11/16"]
REF.
AC OUTPUT
HARNESS
HOT AIR
EXHAUST
TAIL PIPE
EXIT
OIL DRAIN
AIR
INTAKE
48.1
[1 7/8"]
222.7
[8 3/4"]
300.7
[11 13/16"]
369.7
[14 9/16"]
688.3
[27 1/8"]
29
[1 1/8"]
55.5
[2 3/16"]
376.5
[14 13/16"]
5/16"-18 WELDNUTS
(6 PLACES)
82.5
[3 1/4"]
343.4
[13 1/2"]
423.2
[16 11/16"]
717.7
[28 1/4"]
50.8
[2"]
118
[4 5/8"]
223.5
[8 13/16"]
60
[2 3/8"]
210
[8 1/4"]
176.6
[6 15/16"]
83.5
[3 5/16"]
429.5
[16 15/16"]
414.5
[16 5/16"]
360.5
[14 3/16"]
63.5
[2 1/2"]
416
[16 3/8"]
170
[6 11/16"]
79
[3 1/8"]
101
[4"]
TYP.
6.7
[1/4"]
736.4
[29"]
476.4
[18 3/4"]
36.5
[1 7/16"]
[1 7/16
[1 7/16
39.6
[1 9/16"]
69.6
[2 3/4"]
34.3
[1 3/8"]
71.2
[2 13/16"]
211.3
[8 5/16"]
NEG. BAT.
CONNECTION
POS. BAT.
CONNECTION
LP FUEL INLET
VIEW FROM TOP
NOTE: ALL AIR INTAKES AND EXHAUST OUTLETS MUST BE
KEPT CLEAR OF ANY OBSTRUCTIONS. ALL OPEN AREA
IS REQUIRED FOR COOLING.
CONNECTIONS IN
BACK OF GENERATOR
All measurements are in millimeters, 25.4 mm = 1”.