User instructions, General, Lighting the fire – Stovax PR0741 User Manual
Page 4: Turning the fire off, Upgrading your fire
USER INSTRUCTIONS
4
1. GENERAL
1.1 Installation and servicing must only be carried out by a
competent person.
1.2 In all correspondence, please quote the fire type and
serial number, which can be found on the data badge
adjacent to the control knob.
1.3 Ensure that curtains are not positioned above the fire, and
that there is a 300mm minimum clearance between the
sides of the fire and any curtains.
1.4 This product is guaranteed for 2 years from the date of
installation, as set out in the terms and conditions of sale
between Gazco and your local Gazco dealer. Please
consult with your local Gazco dealer if you have any
questions. In all correspondence always quote the Model
Number and Serial Number.
1.5 The decorative front and glass become hot during normal
use and should be treated as a ‘working surface’. It is
therefore recommended that a suitable fire guard be used
for protection of young children and the infirm.
1.6 If any cracks appear in the glass panel do not use the fire
until the panel has been replaced.
2. LIGhTING ThE FIRE
2.1 Locate the control valve on the fire. There are two control
knobs on the valve, the right-hand knob controls the pilot
ignition and the left hand knob controls the main burner.
2.2 If your fire has already been upgraded to battery
remote control, please refer to the instructions provided
with the upgrade to operate the remote control. The
following instructions work for either situation.
1
AR0914
• Ensure that the left-hand control knob is pointing to off (
).
• Ensure that the right-hand control knob is pointing to
off ( ).
• Press in the right-hand control knob and rotate it left until
a click is heard
• Keep pressing in and the knob is pointing to pilot (
)
The pilot should now light. If the pilot has not lit, repeat the
procedure until it does.
• Hold the control knob pressed in 10 seconds and then
release it
The pilot should stay alight. If the pilot goes out, repeat the
steps.
2.3 If the pilot does not light after repeated attempts, contact
the retailer or installer from whom the fire was purchased.
2.4 Turn the right-hand control to point to main burner (
).
The fire can now be controlled using the left-hand
control knob.
2.5 Turn the left-hand control knob to point to low fire (
),
the main burner now lights on low. The burner can
now be controlled between low and high settings.
Turn the control knob anti clockwise to increase the flame
height and clockwise to decrease the height.
2.6 If the pilot flame is extinguished, intentionally or
unintentionally, do not relight the appliance for at least
3 minutes.
3. TURNING ThE FIRE OFF
3.1 To turn the fire off, locate the control valve, turn the left-
hand control knob until it points to off ( ). The main burner
goes out leaving the pilot burning.
3.2 To turn the pilot off, locate the control valve, turn the right-
hand control knob until it points to off ( ). The pilot will
go out.
4. UPGRADING yOUR FIRE
4.1 Your fire is fitted with a control valve that can easily be
upgraded to battery powered remote control. This upgrade
can be fitted by anyone capable of simple DIY jobs and
requires no special training. This upgrade can be obtained
through your local Gazco stockist.
4.2 STANDARD REMOTE CONTROL This remote control can
control the fire after the pilot has been lit. It can turn the
main burner on and regulate it from low through to high
and back again. It can turn the main burner off leaving the
pilot burning GAZCO PART NUMBER 8455.
4.3 PROGRAMMABLE THERMOSTATIC AND TIMER REMOTE
CONTROL. This remote control can control the gas fire
after the pilot has been lit. In MANUAL MODE it can be
used to turn the main burner on and manually regulate it
from low through to high and back again. It can be used to
turn the main burner off, leaving the pilot burning. In
AUTO MODE it will automatically regulate the room
temperature to a preset temperature. In TIMER MODE it
will turn the fire on and off according to preset programme
and automatically regulate the room temperature during
the two periods. GAZCO PART NO. 8456.