beautypg.com

The operating clock setting ("clock sel. ? "), With the jog dial, choose “clock sel, Press the execute/yes key – Fostex D-108 User Manual

Page 122: With the jog dial, choose either “int” or “opt, Press the execute/yes key to process, The setup display stops flashing

background image

122

D-108 Owner’s Manual (Changing the initial setting )

The Operating Clock Setting ("Clock Sel. ? ")

The "The operating clock setting" menu is used to setup the D-108 operating clock. When digital recording is to be made from
external digital equipment (DAT, adat, CD, MD, etc.), the input track is setup by the aforementioned [Digi.in?] (setup of the digital
input track), and whether D-108 is to be operated by the internal clock or externally synchronized with a digital signal from an
external digital equipment, must be selected. In the initial setting, it is specified for D-108 to be synchronized by its own clock
(crystal installed in D-108: Internal) to external digital input signals. The setup content of this [Clock Sel.?] will change partially when
the optional Model 8345 TC/SYNC card is installed in the D-108. For details, read the Model 8345 Operating Manual.

* Initial setting : Int.
* Items which can be set : Int. (internal clock)

: Opt I (Opt I will change to Opt O as long as digital signals are being

* This setting is applicable song by song.
* This setting can be saved or loaded as a part of the song data.
* The setting is memorized even when the power is off.

< Notes at setup of [Clock Sel.?] >

When a digital recording is to be made from external digital equipment (DAT, adat, CD, MD, etc) after
setup of the digital input track, digital input signals from external digital equipment cannot be externally
synchronized should the [Clock Sel.?] setting be maintained in its initial [Int.] setting. Therefore, in order
to digital record by external sync,[Clock Sel.?] must be set to [Opt.]. If digital recording is made while
remaining in the [Int.] setting, it could be the cause in sound deterioration. When D-108 is connected to
a digital mixer, in a system which could create a digital loop depending on the input and output connec-
tions, it is recommended to be used with [Clock Sel.?] set to [Int.] to prevent this digital loop.

1. Press the DISP SEL key and choose the flashing SETUP

mode on the display. Then, press the EXECUTE/YES key.

The SETUP display stops flashing.

2. With the JOG dial, choose “Clock Sel.?”.

The “?” display will start flashing. The display will also show
the current setting. In the case of the initial setting, it will
show “Int”.

3. Press the EXECUTE/YES key.

A blinking [?] will extinguish by pressing the EXECUTE/YES
key and the operating clock information that was lit will
begin blinking.

4. With the JOG dial, choose either “Int” or “Opt” .

If [Int] (initial setting) is selected, the D-108 will operate
using the internal clock.
If [Opt] is selected, the D-108 will will sync to an external
digital signal.

5. Press the EXECUTE/YES key to process.

The selected operating clock will register and [?] in Step 2,
above, will blink.

6. Press the STOP button or EXIT/NO key to come out of this

mode.

The display will go back to the normal time base display.

* Press either the STOP button or EXIT/NO key to return
from the second step menu to the first or to quit SETUP
mode. The menu will go backwards each time you press
either key so that you can correct the setting, choose
some other SETUP mode or eventually return to the nor-
mal time base display.

44.1kHz

SETUP

8

7

6

5

4

3

2

1

42

OL

0

30

24

18

12

9

6

3

44.1kHz

SETUP

8

7

6

5

4

3

2

1

42

OL

0

30

24

18

12

9

6

3

When a digital input track is assigned and the operating clock
set to [Int] (initial setting), if an external digital signal is
correctly input, [DIGITAL] will light in the display.
And, if the D-108 is set to [Opt], [DIGITAL] and [EXT SYNC]
will both light when a digital signal is input. This indicates
that the D-108 is in sync with the external signal.