Power supply and fan tray leds, Table 4, Power supply leds – Force10 Networks Force10 TeraScale E-Series E1200i User Manual
Page 38: Table 5, Fan tray leds

38
Installing AC Power Supplies
•
Two fan trays are installed.
To test the power supplies and fan trays:
Power Supply and Fan Tray LEDs
Step
Task
1.
With the fan trays and power supplies installed, power on the system.
•
Flip the On/Standby switch located next to plug AC-0 to the ON position (down).
2.
Power Supply Status LEDs should be green. If an LED is not lit or is blinking amber:
•
check that the units are properly installed and are plugged into the correct slot.
•
Verify the power source
•
If the LED remains unlit or blinking amber at power up, replace the power supply.
3.
Both fan tray LEDs should be green (online). A blinking green fan tray LED indicates booting. Verify
that air is flowing through the chassis. If a fan tray is not operating properly or air is not flowing through
the chassis:
•
power off the chassis at the remote power source.
•
Ensure that all fan trays are properly installed.
•
Verify the remote power source.
•
If a fan tray LED remains unlit, replace the fan tray.
4.
After you have verified the power and fan operability, power off the chassis to continue the installation
process.
5.
De-energize the Main Disconnect and flip the On-Off switch to the OFF position.
6.
Verify that the LEDs are not lit.
Table 4 Power Supply LEDs
Status
LED is ...
No AC power
Unlit: No connection
Operational (On/Standby switch may be set to Standby)
Lit: GREEN
Power Supply Failure
Lit: AMBER
Table 5 Fan Tray LEDs
Status
LED is ...
Booting
Blinking: GREEN
Fault Detected
Lit: YELLOW
Communication Failure
Blinking: YELLOW