beautypg.com

FUJITSU M3000 User Manual

Page 47

background image

Chapter 3

Troubleshooting

3-9

TABLE 3-4

shows typical messages generated when an error occurs. Messages are

displayed on your console and are recorded in the /var/adm/messages file.

A message in

TABLE 3-4

indicates that the fault has already been diagnosed. If there

was any corrective action that the system could take, the system has already taken it.
If your server is still running, the corrective action continues to be taken.

TABLE 3-4

Predictive Self-Healing Messages

Output displayed

Description

Nov 1 16:30:20 dt88-292 EVENT-TIME:Tue Nov 1
16:30:20 PST 2005

EVENT-TIME: The time stamp of the diagnosis

Nov 1 16:30:20 dt88-292 PLATFORM:SUNW,A70,
CSN:-, HOSTNAME:dt88-292

PLATFORM: A description of the server encountering
the error

Nov 1 16:30:20 dt88-292 SOURCE:eft, REV: 1.13

SOURCE: Information on the Diagnosis Engine used to
determine the error

Nov 1 16:30:20 dt88-292 EVENT-ID:afc7e660-d609-
4b2f-86b8-ae7c6b8d50c4

EVENT-ID: The Universally Unique event ID for this
error

Nov 1 16:30:20 dt88-292 DESC:
Nov 1 16:30:20 dt88-292 A problem was detected in the
PCI Express subsystem

DESC: A basic description of the error

Nov 1 16:30:20 dt88-292 Refer to
http://sun.com/msg/SUN4-8000-0Y for more
information.

WEB SITE: Where to find specific information and
actions for this error

Nov 1 16:30:20 dt88-292 AUTO-RESPONSE:One or
more device instances may be disabled.

AUTO-RESPONSE: What, if anything, the system did
to alleviate any follow-on problems

Nov 1 16:30:20 dt88-292 IMPACT:Loss of services
provided by the device instances associated with this
fault.

IMPACT: A description of what is considered to be the
impact of the fault

Nov 1 16:30:20 dt88-292 REC-ACTION:Schedule a
repair procedure to replace the affected device.Use
Nov 1 16:30:20 dt88-292 fmdump -v -u EVENT_ID to
identify the device or contact Sun for support.

REC-ACTION: A brief description of the corrective
action the system administrator should take