2 removing and replacing a fru, 3 adding a fru into a domain, Removing and replacing a fru – FUJITSU SPARC ENTERPRISE M5000 User Manual
Page 83: Adding a fru into a domain

Chapter 4
FRU Replacement Preparation
4-5
Note –
For a PCI cassette, type the cfgadm -c disconnect command to
disconnect the component from the domain.
The Ap_Id is shown in the output of cfgadm.
iou#0-pci#0
for example.
3. Type the cfgadm command to confirm the component is now disconnected.
4.2.2
Removing and Replacing a FRU
Once the FRU has been removed from the domain, see
4.2.3
Adding a FRU Into a Domain
1. From the Solaris prompt, type the cfgadm command to connect the component
to the domain.
The Ap_Id is shown in the output of cfgadm.
iou#0-pci#0
for example.
2. Type the cfgadm command to confirm the component is now connected.
# cfgadm -a
Ap_Id Type Receptacle Occupant
Condition
iou#0-pci#0 etherne/hp disconnected unconfigured
unknown
iou#0-pci#1 fibre/hp connected configured ok
iou#0-pci#2 pci-pci/hp connected configured ok
# cfgadm -c configure
Ap_Id
# cfgadm -a
Ap_Id Type Receptacle Occupant
Condition
iou#0-pci#0 etherne/hp connected configured ok
iou#0-pci#1 fibre/hp connected configured ok
iou#0-pci#2 pci-pci/hp connected configured ok