FUJITSU SPARC ENTERPRISE M5000 User Manual
Page 280

C-2
SPARC Enterprise M4000/M5000 Servers Service Manual • August 2009
TABLE C-1
identifies the FRU components.
Note –
If the hard disk drive is the boot device, the hard disk will have to be
replaced using cold replacement procedures. However, active replacement can be
used if the boot disk can be isolated from the Solaris OS by disk mirroring software
or other software. The procedure for isolating the hard disk drive from the Solaris
OS varies depending on whether disk mirroring software or other support software
is used. For details, see the relevant software manuals.
TABLE C-1
Midrange Server
FRU Components
Component
Redundant
Cold
Replacement
Hot
Replacement
Active
Replacement
Motherboard unit
No
Yes
Motherboard DC-DC Converter
No
Yes
CPU module
No
Yes
Memory board
Yes
Yes
DIMM No
Yes
eXtended System Control facility unit
No
Yes
I/O unit
No
Yes
I/O DC-DC Converter
No
Yes
I/O DC-DC Converter Riser
No
Yes
PCI cassette
No
Yes
Yes
Yes
Fan Yes
Yes
Yes
Yes
Fan backplane
No
Yes
Power supply unit
Yes
Yes
Yes
Yes
Busbar/I/O backplane/power backplane
(SPARC Enterprise M5000)
No
Yes
I/O backplane/power backplane (SPARC
Enterprise M4000)
No
Yes
Hard disk drive
Yes
Yes
Yes
Yes
Tape drive unit (optional)
No
Yes
Yes
Yes
CD-RW/DVD-RW Drive Unit (DVDU)
No
Yes
Yes
Operator panel
No
Yes