beautypg.com

FUJITSU SPARC ENTERPRISE M5000 User Manual

Page 277

background image

Appendix B

Rules for System Configuration

B-3

I/O unit (IOU)

1

2

Each IOU contains the following:
• PCI cards—Four short PCI Express (PCIe)

slots (four upper slots) and one short PCI-
X slot (lowest slot).

• One I/O controller (IOC) chip, which is

the bridge chip between the system bus
and the IO bus.

• Inter-integrated circuit (I2C) components

for environmental monitoring.

• PCIe switches or bridges connected to the

slots.

You can also add an optional IOBOX, which
contains additional PCIe slots or PCI-X slots.
An IOU requires a CPUM and MEMB on the
same XSB in order to be used. In the case of
quad-XSB, the slots on an IOU are divided up
among the first two parts of a quad-XSB. The
assignments cannot be changed. A separate
CPUM and MEMB are required on each part
of the quad-XSB in order to access the slots of
the IOU assigned to the parts of the quad-
XSB.

PCI cassettes

5 cassettes per
tray in the IOU

• 5 cassettes per

tray in the
IOU

• 2 IOUs (10

cassettes)

PCI cards

5 (1 PCI-X and 4
PCIe)

10 (2 PCI-X and
8 PCIe)

eXtended System Control
facility unit

1

1

The service processor, which operates
independently from the SPARC64™ VI or
SPARC64™ VII processor, is a small system
that directs the system startup,
reconfiguration, and fault diagnosis. This is
where the system management software
(XSCF) runs.

TABLE B-1

System Features (Continued)

Features

SPARC Enterprise
M4000 Server

SPARC Enterprise
M5000 Server

Notes