1. OPERATION

1-9

6. Press ► to show the ARRIVAL TIME sub-menu.

[ARRIVAL TIME]

DATE

[UTC]:

25/APR

TIME[UTC]: 0:00

7. DATE[UTC] is selected; press the ENT key.
8. Enter the date of arrival then press the ENT key.
9. TIME[UTC] is selected; press the ENT key.
10. Enter the estimated time of arrival, in 24-hour notation, then press the ENT

key.

11. Press ► to show the CARGO TYPE sub-menu.

[CARGO TYPE]

TYPE NO.:

00

**** TYPE DETAIL****
NOT AVAILABLE

12. TYPE NO. is selected; press the ENT key.
13. Select type of vessel/cargo, referring to the table on the next page, then

press the ENT key.

Note 1: Only the second digit for the type of vessel is entered here; the first
digit is entered on the INITIAL SETTINGS menu, during installation.

Note 2: When “Tanker” is selected and the Nav status is “Moored”, output
power is automatically switched to 1 W when SOG is less than 3 knots.
Further, in the above condition, when SOG becomes higher than 3 knots,
the pop-up message “CHANGE NAV STATUS?” appears and a beep
sounds. (The pop-up message “TX POWER CHANGED” also appears to
notify you that the Tx power has changed). To erase the pop-up message,
press any key or lower SOG below 3 knots.