FUJITSU MPE3XXXAT User Manual
Page 82
C141-E077-01EN
5 - 15
Table 5.4
Command code and parameters (2 of 2)
Command code (Bit)
Parameters used
7
6
5
4
3
2
1
0
FR SC SN CY DH
STANDBY IMMEDIATE
1
1
0
1
0
1
1
0
0
0
1
0
0
0
0
0
N
N
N
N
D
SLEEP
1
1
0
1
0
1
1
0
1
0
0
1
0
1
1
0
N
N
N
N
D
CHECK POWER MODE
1
1
0
1
0
1
1
0
1
0
0
1
0
0
0
1
N
N
N
N
D
SMART
1
0
1
1
0
0
0
0
Y
Y
Y
Y
D
FLUSH CACHE
1
1
1
0
0
1
1
1
N
N
N
N
D
SECURITY DISABLE PASSWORD
1
1
1
1
0
1
1
0
N
N
N
N
D
SECURITY ERASE PREPARE
1
1
1
1
0
0
1
1
N
N
N
N
D
SECURITY ERASE UNIT
1
1
1
1
0
1
0
0
N
N
N
N
D
SECURITY FREEZE LOCK
1
1
1
1
0
1
0
1
N
N
N
N
D
SECURITY SET PASSWORD
1
1
1
1
0
0
0
1
N
N
N
N
D
SECURITY UNLOCK
1
1
1
1
0
0
1
0
N
N
N
N
D
SET MAX ADDRESS
1
1
1
1
1
0
0
1
N
Y
Y
Y
Y
READ NATIVE MAX ADDRESS
1
1
1
1
1
0
0
0
N
N
N
N
D
Notes:
FR : Features Register CY: Cylinder Registers
SC : Sector Count Register DH : Drive/Head Register
SN : Sector Number Register
R: R = 0 or 1
Y: Necessary to set parameters
Y*: Necessary to set parameters under the LBA mode.
N: Necessary to set parameters (The parameter is ignored if it is set.)
N*: May set parameters
D: The device parameter is valid, and the head parameter is ignored.
D*: The command is addressed to the master device, but both the master device and the
slave device execute it.
X: Do not care
Command name