beautypg.com

FUJITSU MPE3XXXAT User Manual

Page 106

background image

C141-E077-01EN

5 - 39

Table 5.7

Diagnostic code

Code

Result of diagnostic

X‘01’
X‘03’
X‘05’
X‘8x’

No error detected.
Data buffer compare error
ROM sum check error
Failure of device 1

At command issuance (I/O registers setting contents)

1F7

H

(CM)

1

0

0

1

0

0

0

0

1F6

H

(DH)

Ч

Ч

Ч

DV

xx

1F5

H

(CH)

1F4

H

(CL)

1F3

H

(SN)

1F2

H

(SC)

1F1

H

(FR)

xx
xx
xx
xx
xx

At command completion (I/O registers contents to be read)

1F7

H

(ST)

Status information

1F6

H

(DH)

00

1F5

H

(CH)

1F4

H

(CL)

1F3

H

(SN)

1F2

H

(SC)

1F1

H

(ER)

00
00

01

H

01

H

Diagnostic code

(17)

FORMAT TRACK (X'50')

Upon receipt of this command, the device sets the DRQ bit and waits the completion of 512-
byte format parameter transfer from the host system. After completion of transfer, the device
clears the DRQ bits, sets the BSY bit. However the device does not perform format operation,
but the drive clears the BYS bit and generates an interrupt soon. When the command
execution completes, the device clears the BSY bit and generates an interrupt.

The drive supports this command for keep the compatibility with previous drive only.

(18)

READ LONG (X'22' or X'23')

This command operates similarly to the READ SECTOR(S) command except that the device
transfers the data in the requested sector and the ECC bytes to the host system. The ECC error
correction is not performed for this command. This command is used for checking ECC
function by combining with the WRITE LONG command.