C141-E077-01EN

6 - 12

(2)

Alternate cylinder assignment

A defective sector is assigned to the spare sector in the alternate cylinder.

This processing is performed when a physical track contains three or more defective sectors,
and when the automatic alternate processing is performed.

Figure 6.8 shows an example where (physical) sector 5 is detective on head 0 in cylinder 0.

5

7

6

4

3

1

300

299

2

Index

Cylinder 0

Head 0

Head 0

Already

assigned

Defective

sector

4 alternate cylinders are provided for each head in zone 13 (inner side).

When an access request to sector 5 is specified, the device accesses the alternated sector in the
alternate cylinder instead of sector 5. When an access request to sectors next to sector 5 is
specified, the device seeks to cylinder 0, head 0, and continues the processing.

Defective sector is assigned to unassigned sector.

(unused)

Sector (logical)

Sector (physical)

Alternate
cylinder

2

1

4

3

6

7

299

298

Figure 6.8

Alternate cylinder assignment

(3)

Automatic alternate assignment

The device performs the automatic assignment at following case.

1) When ECC correction performance is increased during read error retry, a read error is

recovered.

Before automatic alternate assignment, the device performs rewriting the corrected data to
the erred sector and rereading. If no error occurs at rereading, the automatic alternate
assignment is not performed.

2) When a write error occurs and the error does not recovered.

407

408

1 alternate cylinder is provided in outer side.

299

300

405

406