Table 3-1. Network Health Meters

Icon

Description

Press to display network utilization.

Percent Display – Displays the utilization percentage for the last one-second sample period.

Count Display – Displays the frame count, for the last one-second sample period.

The meter’s scale switches to high range when the frame rate exceeds 10,000/second.

Press to display the types of errors received.

Percent Display – Displays the number of errors as a percentage of the number of frames
received for the last one-second sample period.

Errors counted are: bad FCS, short frames, late collisions, and jabbers.

Count Display – Displays the error count for the last one-second sample period.