28

INSTALLATION

buildup and free of restrictions allows clothes to

dry faster and reduces energy use.

NOTE

• The appliance should be cool before starting this

test. If the appliance was warmed up during

installation, run the

Air Dry

cycle for a few

minutes to reduce the interior temperature.

Activating the Installation Test

1

Remove the drying rack (on some models)

and literature, and then close the door.

• Do not load anything in the drum for this

test, as it may affect the accuracy of the

results.

2

Press the

Power

button then IMMEDIATELY

press and hold the

Low Static

and

Options

buttons.
• This button sequence activates the

installation test. A message will display if

the activation is successful.

3

Press the

Start/Pause

button.

• The appliance will start the test, which will

last a few minutes. The heat will be turned

on and the temperatures in the drum will be

measured.

4

Check the display for results.
• During the test cycle, monitor the Flow

Sense

TM

display on the control panel. If the

Flow Sense

TM

LED has not turned on when

the cycle ends, the exhaust system is

adequate. If the exhaust system is severely
restricted, the Flow Sense

TM

LED will turn

on. Other problems may also be shown with

error codes. See the chart on the next page

for error code details and solutions.

• If the Flow Sense

TM

LED indicates that the

exhaust system is severely restricted, have

the system checked immediately, as

performance will be poor.

5

End of cycle.
• At the end of the test cycle, a message will

display. The test cycle will end and the

appliance will shut off automatically after a

short delay.

Check the Duct Condition

If the Flow Sense

TM

LED is turned on, check the

exhaust system for restrictions and damage.

Repair or replace the exhaust system as needed.

NOTE

• When the appliance is first installed, this test

should be performed to alert you to any existing

problems with the exhaust duct in your home.

However, since the test performed during

normal operation provides more accurate

information on the condition of the exhaust duct

than the installation test, the results during the

two tests may not be the same.

• Do not interrupt the test cycle, as this could

result in inaccurate results.

• Even if the LED doesn't light up during the test

cycle, some restrictions may still be present in

the exhaust system. Refer to the

Venting the

Dryer

section of this manual for complete

exhaust system and venting requirements.

Error Codes

Check the error code before you call for service.

en-us_main.book.book Page 28 Wednesday, December 7, 2022 8:18 AM