View alarms, Display all alarms, Display active alarms – Quintum Technologies Tenor Call Relay SP User Manual
Page 56: View alarms -7, Display all alarms -7, Display active alarms -7
![background image](https://www.manualsdir.com/files/801760/content/doc056.png)
5-6
P/N 480-0048-00-10
Chapter 5: System Alarms
View Alarms
The Command Line Interface (CLI) enables you to view alarms through the Monitor mode. You can view
active alarms, as well as view an alarm history list.
You are now ready to view active alarms and an alarm history, or both.
For information about accessing the CLI, see Chapter 4: Configuring Call Relay SP via CLI.
Display all Alarms
You are able to display both active alarms and an alarm history as follows:
1. Through CLI, access the Monitor prompt.
2. Type alarm. Both active alarms and the alarm history will be displayed. See section How to Read Alarms
for field definitions.
Figure 5-1 Alarm sample
Display Active Alarms
1. Through CLI, access the Monitor prompt.
2. Type alarm a. The active alarms will be listed. See section How to Read Alarms for field definitions. If
you enter alarm without a command following it, both active alarms and the alarm history will be dis-
played.
Figure 5-2 Active Alarm Sample
IP#:Sequence#:Severity:Type:Desc:Slot#:Device#:Line#:Channel#:Date/Time
193.173.179.185:602:ALR:3:Border Element connection lost:0:0:0:0:FRI FEB 22 21:48:53 2002
IP#:Sequence#:Severity:Type:Desc:Slot#:Device#:Line#:Channel#:Date/Time
193.173.179.185:602:ALR:3:Border Element connection lost:0:0:0:0:FRI FEB 22 21:48:53 2002