Boiler design, Safety devices, Servicing, maintenance and spare parts – Glow-worm Ultracom hxi User Manual
Page 6: Introduction, Range rating, Electrical supply failure, Overheating safety, Frost protection, Condensate drain blockage, Condensate drain
0020107233_00 - 06/11 - Glow-worm
INTRODUCTION
- 6 -
boiler
Design
boiler Design
These boilers are designed to provide central heating from
a fully pumped open vented or sealed water system and
domestic hot water using a fully indirect cylinder.
Once the controls are set the boiler operates automatically.
Range Rating
These boilers are fully modulating, it is therefore not
necessary to range rate them.,however, if desired, it is
possible to range rate the 38hxi max. CH output in 1kW
increments, refer to section 10.
electrical Supply failure
The boiler will not work without an electrical supply.
Normal operation of the boiler should resume when the
electrical supply is restored.
Reset any external controls, to resume normal operation of
the central heating.
If the boiler does not resume normal operation press the reset
button. If the boiler does not resume normal operation after
this call your Installation/Servicing company or Glow-worm
service.
overheating Safety
The boiler software is designed to recognise the potential for
an overheat lockout and will shutdown before this happens.
To restart the boiler, press the reset button on the controls
fascia.
If the boiler fails to resume normal operation and all external
controls are calling for heat, then call your Installation/
Servicing company or Glow-worm service.
Safety Devices
frost protection
The appliance has a built in frost protection device that
protects the boiler from freezing. With the gas and electric
supplies ON and irrespective of any room thermostat setting,
the frost protection device will operate the pump when the
temperature of the boiler water falls below 8
O
C.
A timer is used so that the temperature can be checked
periodically. After 10 minutes the pump will be stopped if the
temperature is higher than 10
O
C or has already reached 35
O
C.
The burner will activate if the boiler temperature does not
reach 10
O
C after 30 minutes or at any time if the temperature
drops to 5
O
C.
The burner will switch off when the temperature reaches
35
O
C.
Condensate Drain blockage
As a safety feature the
boiler
will stop working if the
condensate drain becomes blocked. During freezing
conditions this may be due to the forming of ice in the
condense drain external to the house. Release an ice
blockage by the use of warm cloths on the pipe. The boiler
should then restart.
Condensate Drain
A plastic drain pipe must be fitted to allow discharge of
condensate to a drain.
Condensate should, if possible, be discharged into the internal
household draining system. If this is not practical, discharge
can be made externally into the household drainage system or
a purpose designed soak away, see section 8 for more details.
Pluming from flue terminal
Like all condensing boilers this appliance will produce a plume
of condensation from the flue terminal in cool weather. This is
due to the high efficiency and hence low flue gas temperature
of the boiler. This is normal and not an indication of a fault.
Servicing, Maintenance
and Spare Parts
Servicing and Maintenance
To ensure the continued efficient and safe operation of the
boiler it is recommended that it is checked and serviced as
necessary at regular intervals. The frequency of servicing will
depend upon the particular installation conditions and usage.
If this
appliance
is installed in a rented property there is a duty
of care imposed on the owner of the property by the current
issue of the Gas Safety (Installation and Use) Regulations,
Section 35.
Servicing/maintenance should be carried out by a
competent
person approved at the time by the Health and Safety
Executive in accordance with the rules in force in the
countries of destination.
To obtain service, please call your installer or Glow-worm’s
own service organisation using the telephone number on the
inside front cover of this literature.
After servicing, complete the relevant Service Interval Record
section of the Benchmark Checklist located on the inside back
pages of these instructions.
Spare Parts
Remember, when replacing a part on this appliance, use
only spare parts that you can be assured conform to the
safety and performance specification that we require. Do not
use reconditioned or copy parts that have not been clearly
authorised by Glow-worm.
If a part is required contact Glow-worm’s own service
organisation using the telephone number on the inside front
cover of this
booklet.
Please quote the name of the
appliance,
this information will
be on the name badge on the front of the appliance.
If in doubt seek advice from the local gas company or Glow-
worm’s own service organisation using the telephone number
on the inside front cover of this booklet.