INSTALLATION
- 10 -
4 evacuation of combustion Gas
4.1 Regulation
Only flue accessories supplied by Glow-worm
must be used.
Different flue outlet configurations can be carried out.
• Consult your supplier for more information about the other
possibilities and associated accessories.
44 mm/m
• Standard flue terminal kits have an in-built fall back to the
boiler to drain the condensate. These can be fitted level
between the appliance and the termination position. All
other extended flues must have a fall of at least 44mm/m
The maximum length of the flue outlet is defined according to
its type (for example C13).
• Whatever the kind of flue system chosen, observe the
minimum distances indicated in the chart below to position
the flue terminals.
• To install the flue, refer to the separate flue instruction
supplied with your appliance.
• Explain these requirements to the user of the appliance.
a
If necessary, you must install terminal
protection.
Caution! The connection between the flue
elbow and the flue outlet must be sealed.
In Gb the minimum acceptable siting dimensions for the
terminal from obstructions, other terminals and ventilation
openings are shown in diagram overleaf.
In Ie the minimum distances for flue terminal positioning must
be those detailed in I.S.813 “Domestic Gas Installations”.
The terminal must be exposed to the external air, allowing
free passage of air across it at all times.
Being a condensing boiler some pluming may occur from
the flue outlet. This should be taken into consideration when
selecting the position for the terminal.
Carports or similar extensions of a roof only, or a roof and
one wall, require special consideration with respect to any
openings, doors, vents or windows under the roof. Care is
required to protect the roof if made of plastic sheeting. If
the carport comprises of a roof and two or more walls, seek
advice from the local gas supply company before installing
the boiler.
If the flue terminal is positioned near a light
source insects may enter the flue system.
Where safe and practical to do so advise the
homeowner to check the flue outlet and clear
visible insects from the terminal end.
H* and J* See diagram 4.2. These dimensions comply with
the building regulations, but they may need to be increased to
avoid wall staining and nuisance from pluming depending on
site conditions.
Terminal Guard
A terminal guard is required if persons could come into contact
with the terminal or the terminal could be subject to damage.
If a terminal guard is required, it must be positioned to provide
minimum of 50mm clearance from any part of the terminal and
be central over the terminal.
The guard should be similar to that shown in diagram 4.1.
A suitable guard is manufactured by: -
Tower Flue Components
Morley Rd.
Tonbridge
Kent TN9 1RA.
Size: 280mm x 165mm. Part No: CGDK3
Diagram 4.1