8 Frame relay configuration

Nortel Secure Router 8000 Series

Configuration -WAN Access

Run the

interface

interface-type interface-number command to enter the FR interface

view.

Run the

interface mfr

interface-number command to enter the MFR interface view.

Step 3

Run:

fr Imi type { ansi | nonstandard | q933a }

The FR LMI type is configured.

Step 4

Run:

timer hold seconds

The command configures the polling interval (determined by T391) on the DCE device.

Step 5

Run:

fr Imi n391dte n391-value

The command configures the LMI N391 parameters on the DTE device.

Step 6

Run:

fr Imi n392dte n392-value

The command configures the DTE N392 parameter.

Step 7

Run:

fr Imi n393dte n393-value

The command configures the DTE N393 parameter.

—End

8.5.3 Configuring frame relay LMI and related parameters of DCE

Do as follows on the routers:

Step 1

Run:

system-view

The system view appears.

Step 2

Choose one of the following steps to enter the corresponding interface view as required.

Run the

interface

interface-type interface-number command to enter the FR interface

view.

Run the

interface mfr

interface-number command to enter the MFR interface view.

Step 3

Run:

fr Imi type { ansi | nonstandard | q933a }

The command configures the FR LMI type.

Step 4

Run:

fr Imi t392dce t392-value