beautypg.com

Fault description, Fault analysis, Troubleshooting procedure – Nortel Networks 8000 User Manual

Page 281

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

7 LAPB and X.25 configuration

Nortel Secure Router 8000 Series

Configuration -WAN Access

Step 2

After configuring the VC range, use the

shutdown

command and the

undo shutdown

command to activate the configuration.

—End

7.9.7 After SVC application of XOT is configured, the ping fails

Fault description

After you configure the SVC application of XOT, the ping operation fails.

Fault analysis

The possible causes are:

The physical connection is in the faulty condition.

SVC is configured incorrectly.

XOT is configured incorrectly.

Troubleshooting procedure

Do as follows on the routers:

Step 1

Check whether the interface status and the protocol status are Up.

Step 2

If the interface is Down, check whether the physical connection and configuration are correct.

Step 3

Check whether the SVC is configured correctly.

Step 4

Check whether the XOT is configured correctly.

—End

7.9.8 After PVC application of XOT is configured, the ping fails

Fault Description

After you configure the SVC application of XOT, the ping operation fails.

Fault analysis

The possible causes are:

The physical connection is in the faulty condition.

PVC is configured incorrectly.

XOT is configured incorrectly.

Troubleshooting procedure

Do as follows on the routers:

Step 1

Check whether the interface status and the protocol status are Up.

7-78

Nortel Networks Inc.

Issue 5.3 (30 March 2009)