Exterior or in-line blower selection, Install the ductwork – Broan 63000EX User Manual
Page 5
- 5 -
EXTERIOR OR IN-LINE BLOWER SELECTION
CAUTION: Either an exterior blower or in-line blower may be used with this hood.
The 63000EX series hood must be installed with blower models 331H, 332H, 335,
336, HLB3, HLB6, HLB9 or HLB11 only. Other Blowers cannot be substituted
(Blowers sold separately).
The blower must be UL listed for Canadian and U.S. use, and evaluated for use with
solid state speed control, rated 120V, 60 Hz, 6.0 A max.
8”ROUND
DUCT
INSTALL THE DUCTWORK
NOTE: To reduce the risk of fire, use only metal ductwork.
1. Choose the location where the Exterior or In-Line Blower will be mounted. See
illustrations below for mounting location suggestions and restrictions.
2. A straight, short duct run will allow the hood to perform most efficiently.
3. Long duct runs, elbows and transitions will reduce the performance of the
hood. Use as few of them as possible. Larger ducting may be required for best
performance with long duct runs.
4. After the Exterior or In-Line Blower has been installed, connect round metal
ductwork and work back towards the hood location. Use duct tape to seal joints
between ductwork sections.
5. An 8” round to 10” round transition (Model 414) is required. For best air
performance, install the transition as close to the range hood as possible.
OK
OK
SUGGESTED MOUNTING LOCATIONS
EXTERIOR BLOWER
CAUTION: MAY NOT FIT
UNDER EAVES OF SINGLE
STORY HOMES
24” TO 30” ABOVE
COOKING SURFACE
DECORATIVE
FLUE
8” TO 10”
ROUND
TRANSITION
8” ROUND
ELBOW
10”
ROUND
DUCT
10” ROUND
DUCT
EXTERIOR
BLOWER
HOOD
EXTERIOR
BLOWER