beautypg.com

86037400-pg-4-14_5-1, Maintenance – Prochem Legend XL User Manual

Page 39

background image

MAINTENANCE

86037400 06/30/09

4-14

PROBLEM CAUSE SOLUTION

Starter turns over engine, but
will not start

Engine is malfunctioning

Refer to Kohler Engine Operation and
Maintenance Manual.

Engine is out of gasoline

Add gasoline to the fuel tank.

Waste tank is full

Empty waste tank.

Main or engine circuit breaker on
the control panel has been tripped.

After inspecting the unit to determine the
cause of the tripped circuit breaker, press
the reset button.

Defective fuel pump.

Replace fuel pump.

Defective float switch inside the
waste tank.

Check switch for proper operaton. Replace
as necessary.

Oil pressure gauge on engine has
shut down, due to insufficient oil
pressure.

Refer to the Kohler Engine Operation and
Maintenance Manual. DO NOT restart the
engine until the cause is determined and
corrected.

Engine stops running
While doing normal cleaning,
the engine stops running

No ignition in the engine or engine
is malfunctioning.

Refer to the Kohler Engine Operation and
Maintenance Manual.

Flow restriction caused by hard
water scaling.

Descale unit, repair or replace damaged
plumbing components as necessary.
Install water softener.

Excessive heating

Not enough water flow.

Check jet size of tool.

Heat exchanger leaks

NOTE: The heat exchanger will
produce water condensation
discharge at times during
normal operation. DO NOT
confuse this with a leak.

Engine/vacuum exhaust heat
exchangers are damaged from
frozen water.

Inspect heat exchangers for leaks. Visually
inspect for damage. Pressure check after
removing from the unit. (Maximum test
pressure 1200 PSI).

Temperature relief valve on water
box is stuck open.

Clean temperature relief valve and test.
Replace, if necessary.

Engine RPM is low.

Reset engine RPM.

Loss of temperature

The heat output of the unit is
LESS than normal.

Defective temperature gauge.

Test gauge and sensor. Replace failed
component.

Defective waste pump float switch.

Replace float switch.

Broken diaphragm.

Replace diaphragm.

Weak battery.

Charge or replace battery if needed.

Check charging station.

Automatic waste pump is
malfunctioning or not operating
normally

NOTE: When replacing either
the pump or float switch, use
new electrical connectors and
heat shrink. Inspect connection
for watertight seal.

Pump-out circuit breaker on control
panel has been tripped.

After inspecting waste pump to determine
the cause of the tripped circuit breaker,
press the reset button.